Application Information
- Meet NEC Class I/Division 1 (Groups C and D) for use in Hazardous Locations
- Terminal or Junction Box required that meets CI/D1 standards
- Ambient rating: +40°C. Environmental protection: IP-66, TENV
- For variable speed operation, an AC speed control (Inverter / VFD) is required
- Winding options are either 230/60/3 or 460/60/3
- Face mounting is standard; Base mount, model 0931, is optional
- Explosion-Proof Motors; UL Listed for US and Canada
Optional Accessories
STANDARD FEATURES
- Motors meet NEC Class I/Division 1 (Groups C and D, Temp Code T3C and T4A) for use in hazardous location environments where ignitable concentrations of flammable gases, vapors or liquids are likely to exist under normal operating conditions; Explosion-Proof Motors are UL Listed for US and Canada
- 230VAC or 460VAC, Inverter-duty 3-phase, 60Hz Variable speed, maintenance free AC motor
- Terminal or Junction Box required that meets CI/D1 standards
- Ambient rating +40°C max. Environmental protection: IP-66, TENV
- For variable speed operation, an AC speed control (Inverter / VFD) is required
- Face mounting is standard; Base mount is optional (model 0931)
-
5.875” B.C. meets NEMA-56C specifications with optional base mount kit, model 0931, installed. And NEMA-42C face mount with ø3.750 B.C. Motor shaft diameter 5/8-inch (0.625”) with key.